상세 보기
냉간성형 탄소강 이면전단 볼트접합부 최대내력에 관한 실험적 고찰
- Jeong, Wonhun;
- Kim, Junsu;
- Kim, Taesoo
SCOPUS
1초록
In this study, experiments with monotonic tensile loading have been performed to investigate the structural behaviors such as ultimate strength and fracture mode of double shear cold-formed carbon steel two-bolted connection and four-bolted connection with varied end distances for providing the basic data of domestic design specification draft for cold-formed carbon steel bolted connection. Main variables are bolt arrangement (2 columns × 1 row and 2 columns × 1 rows) and end distance parallel to the direction of applied load. Specimens with two bolts failed by block shear fracture. Four-bolted connection showed two types of fracture mode at test end such as block shear fracture and tensile net-section fracture at test end. Moreover, test ultimate strengths were compared with those by current design specifications (Korean Design Standard (KDS)/American Institute of Steel Construction (AISC), Eurocode 3 (EC3), Canadian Standards Association (CSA), American Iron and Steel Institute (AISI), Architectural Institute of Japan (AIJ) and strength equations suggested by previous studies for carbon steel bolted connection. © 2022 Architectural Institute of Korea.
키워드
- 제목
- 냉간성형 탄소강 이면전단 볼트접합부 최대내력에 관한 실험적 고찰
- 제목 (타언어)
- An Experimental Investigation on Ultimate Strength of Cold-formed Carbon Steel Double-shear Bolted Connections
- 저자
- Jeong, Wonhun; Kim, Junsu; Kim, Taesoo
- 발행일
- 2022-05
- 유형
- Article
- 저널명
- 대한건축학회논문집
- 권
- 38
- 호
- 5
- 페이지
- 235 ~ 242
- 언어
- KOR
- 출판사
- 대한건축학회
- 발행국가
- 대한민국
- 분량
- 8 페이지
- ISSN
- E 2733-6247
P 2733-6239