상세 보기
유동안정화 장치가 홴 테스터의 성능에 미치는 영향
- 최영석;
- 김덕수;
- 윤준용
초록
In this study, the effect of flow settling means on the performance of fan tester were numerically investigated by using a computational fluid dynamics(CFD). The airflow rate was calculated from the pressure differential across a flow nozzle in the measuring plane and the flow settling means were generally installed in the chamber of the fan tester to provide proper airflow patterns ahead of the measuring plane. The predicted nozzle differential pressures with uniform inlet velocities were compared with the values of the ANSI/AMCA 210-99 to verify the performance of the commercial CFD code CFX 5.6. The influence of flow settling means on the measurement of airflow rate in a fan tester were discussed with various porosities and inlet jet velocities. The results obtained show that the proper band of porosities exist to meet the AMCA standard in a specified inlet jet velocity.
키워드
- 제목
- 유동안정화 장치가 홴 테스터의 성능에 미치는 영향
- 제목 (타언어)
- Effects of Flow Settling Means on the Performance of Fan Tester
- 저자
- 최영석; 김덕수; 윤준용
- 발행일
- 2005-10
- 저널명
- 한국유체기계학회 논문집
- 권
- 8
- 호
- 5
- 페이지
- 29 ~ 34
- 언어
- KOR
- 출판사
- 한국유체기계학회
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- P 2287-9706