상세 보기
철골조 모듈러 유닛의 현장시공 보-보 결합 구조체의 3시간 내화성능에 관한 실험적 연구
- 장활제;
- 송재은;
- 김양범;
- 김경수;
- 안용한
SCOPUS
0초록
This study aims to assess the 3-hour fire resistance capabilities of a beam-to-beam combination structure, mirroring the on-site assemblyfeatures of the modular construction method. A specific detail for the 3-hour fire resistance of the beam-to-beam combination structure wasput forth, followed by a non-load heating test utilizing a horizontal heating furnace. In this proposed detail, fireproof gypsum boards coverthe beams of individual modular units, the linear joint between on-site installed beams is filled with fireproof insulation or ceramic wool, anda fireproof sealant is applied for non-flammability assurance. The results from two rounds of 3-hour fireproof tests demonstrated satisfactoryfireproof performance.
키워드
- 제목
- 철골조 모듈러 유닛의 현장시공 보-보 결합 구조체의 3시간 내화성능에 관한 실험적 연구
- 제목 (타언어)
- Experimental Exploration of 3-Hour Fire Resistance in Beam-to-Beam Combination Structures within Steel Structure Modular Units
- 저자
- 장활제; 송재은; 김양범; 김경수; 안용한
- 발행일
- 2024-02
- 저널명
- 대한건축학회논문집
- 권
- 40
- 호
- 2
- 페이지
- 261 ~ 266
- 언어
- KOR
- 출판사
- 대한건축학회
- 발행국가
- 대한민국
- 분량
- 6 페이지
- ISSN
- E 2733-6247