Synergistic Effect of He and H on the Surface Swelling of Ion-implanted Ti/Ta-added Reduced Activation Ferritic/Martensitic Steel for Fusion Reactors

  • Kim, Sangeun; 
  • Jin, Hyung-Ha; 
  • Kim, Hyeongchul; 
  • Heo, Jungwoo; 
  • Cho, Seong-Yong; 
  • 외 3명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Surface swelling caused by He implantation was studied for newly-developed Ti/Ta-added reduced-activation ferritic/martensitic (RAFM) steels. Post-implantation annealing at 623 K for 2 h of He-implanted RAFM-steel samples led to surface-step formation because of surface swelling induced by He bubbles formed inside the samples. Pre-implantation of a small number of H ions was found to cause an increase in the surface-step height, which was not expected. A possible mechanism for this synergistic effect of pre-implanted H is proposed. © 2020, The Korean Physical Society.

키워드

Helium bubble; RAFM steel; Surface swelling; Synergistic effects; FERRITIC-MARTENSITIC STEEL; HELIUM IRRADIATION; MICROSTRUCTURE; HYDROGEN; EVOLUTION; COMPLEXES; POSTIRRADIATION; EMBRITTLEMENT; TENSILE; ALLOYS