Corrosion behavior of buried pipeline on subjected to cold weather and pH difference

초록

The present study concerns a corrosion behavior of buried pipeline on weld zone subject to frost and chemical deterioration. To access corrosion monitoring test, carbon steel was buried in the sand. Considering the pH of soil, sand was prepared having pH level (i.e. pH 5, 7 and 9). To evaluate the effect of temperature, some specimens were placed in chamber condition of -15 ˚C for about 1 month, other specimens were putted in chamber condition of 15 ˚C and the other specimens were placed in chamber condition of 15 ˚C for control. To accelerate the corrosion of buried steel, sodium chloride was induced in the sand. Then, the corrosion behavior of buried pipe was monitored. For monitoring, galvanic current and mass loss method were performed. As a result, the specimen which had temperature change had the highest corrosiveness. In addition, a significant relationship between corrosion potential and pH of sand was presented.

제목
Corrosion behavior of buried pipeline on subjected to cold weather and pH difference
저자
안기용
발행일
2016-05-18