Reliable quantification of trace diarrhetic shellfish poisoning toxins in high-lipid bivalves by UHPLC-ESI-MS/MS in time segment polarity switching mode: Comparison of three extraction methods

  • Lee, Myoung Eun
  • Ko, Keon-hee
  • Park, Na-Hyun
  • Lee, Wonwoong
  • Yoo, Hye Hyun
  • 외 3명
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Analysis of marine biotoxins in high-lipid bivalves has several limitations due to the coexistence of lipid matrices, low biotoxin concentrations, and the different physiochemical properties of the various biotoxins. In this study, a sensitive and reliable method to simultaneously determine six diarrhetic shellfish poisoning (DSP) toxins (five acidic and one neutral biotoxins) in oysters and mussels was developed based on UHPLC-MS/MS-multiple ion reaction monitoring (MRM) using time segment polarity switching. For effective sample pretreatment, three protocols including syringe filtration, Strata (TM)-X solid phase extraction (SPE), and freezing lipid filtration combined with SPE (FLF + SPE) were evaluated, and FLF + SPE method was shown to be the most effective with high lipid removal efficiency. Aging effects of the UHPLC mobile phase on MS detection sensitivity and retention time shift of DSP toxins were carefully examined. The developed method provided good recoveries ranging from 81.0 to 119.6%, showing no significant matrix effect and assay was linear with coefficients of determination above R-2 > 0.99 for all analytes. Validation tests using a certified reference material (CRM) and spiking DSP toxins (OA and DTX-1 at 1.07 mu g/g, and DTX-2 at 0.86 mu g/g) showed this method to be acceptable, with a relative standard deviation of < 0.17% and recovery ranging from 87.29 to 109.97%. Finally, the established method was successfully applied to quantify DSP toxins in 40 oyster and mussel samples collected from Korean fishery markets, ensuring sea food safety.

키워드

High-lipid bivalvesDiarrhetic toxinsFreezing-lipid filtrationMobile phase agingTime segment polarity switchingUHPLC-ESI-MS/MSTANDEM MASS-SPECTROMETRYLIPOPHILIC MARINE TOXINSOKADAIC ACIDSEAFOODCHINAVALIDATIONBIOTOXINSSAMPLESSEA
제목
Reliable quantification of trace diarrhetic shellfish poisoning toxins in high-lipid bivalves by UHPLC-ESI-MS/MS in time segment polarity switching mode: Comparison of three extraction methods
저자
Lee, Myoung EunKo, Keon-heePark, Na-HyunLee, WonwoongYoo, Hye HyunLee, JeongmiChoi, Yong SeokHong, Jongki
DOI
10.1016/j.microc.2018.08.043
발행일
2018-12
유형
Article
저널명
Microchemical Journal
143
페이지
441 ~ 449