상세 보기
초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구
- 백영훈;
- 육태원;
- 박동수;
- 김한솔;
- 이한승
초록
The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards
키워드
- 제목
- 초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구
- 제목 (타언어)
- A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete
- 저자
- 백영훈; 육태원; 박동수; 김한솔; 이한승
- 발행일
- 2023-11
- 유형
- Proceeding
- 저널명
- (사)한국건축시공학회 봄학술발표대회 논문집
- 권
- 23
- 호
- 2
- 페이지
- 41 ~ 42
- 언어
- KOR
- 출판사
- 한국건축시공학회
- 발행국가
- 대한민국
- 분량
- 2 페이지