상세 보기
Segmental Wedge를 이용한 차압식 유량측정 방법
- 윤준용;
- 성낙원
초록
The discharge coefficient in segmental wedge having ninety degrees vertex angle for the five kinds of opening ratio with differential pressure taps located at both upstream and downstream of one diameter of pipe was measured .main purpose of this work is placed on developing the proper form of an equation for the discharge coefficient of a segmental wedge used as a primary element of flow metering devices, and from thata six-term equation which can express the variability of opening ratios was developed. The same assumption and hypotheses were used and tested for all procedures as conventional differential producers; however, the range of the opening ratio over this work is more expanded than previous studies. The opening ratios of segmental wedge, namely 0.3, 0.4, 0.5, 0.6 and 0.7 were investigated the Reynolds number based on the spool inside diameter ranges from 12,000 to 380,000, the resulting equation for the discharge coefficient is relatively simple; it contains only one variable-opening ratio because the characteristic of discharge coefficient of segmental wedge has little connection with the Reynolds number as shown by previous studies.
키워드
- 제목
- Segmental Wedge를 이용한 차압식 유량측정 방법
- 제목 (타언어)
- Flowrate Measurement Using Segmental Wedge as a Restriction Device for Differential Pressure
- 저자
- 윤준용; 성낙원
- 발행일
- 2005-12
- 저널명
- 유체기계 연구개발 발표회 논문집
- 페이지
- 302 ~ 307
- 언어
- KOR
- 출판사
- 한국유체기계학회
- 발행국가
- 대한민국
- 분량
- 6 페이지