Corrosion risk of steel fibre in concrete

Citations

WEB OF SCIENCE

67
Citations

SCOPUS

76

초록

In the present study, the corrosion risk of steel fibre in concrete was assessed by measuring the corrosion rate of steel fibre in chloride-contaminated mortar. Simultaheously, the rate of chloride transport in steel fibre mortar was determined by chloride profiles. Then, the interface of the steel fibre was examined by the scanning electron microscopy to ensure the porosity in the vicinity. As a result, it was found that the corrosion resistance of steel fibre against chloride was slightly higher than for reinforcing steel rebar in concrete, presumably due to the presence of mille scale on the surface; the chloride threshold level ranged 0.8-1.0% by weight of cement. However, transport of chloride ions in concrete containing steel fibre was accelerated by increased porosities in the vicinity of steel fibre, implying that external aggressive ions may easily penetrate the concrete then to chemically degrade concrete properties. In fact, the diffusion coefficient of chloride in mortar containing steel fibre ranged 4.79-9.61 x 10(-12) m(2)/s, as being 2-3 times higher for steel fibre-free mortar. (C) 2015 Elsevier Ltd. All rights reserved.

키워드

Steel fibre; Corrosion; Chloride; Concrete; Porosity; RESISTANCE
제목
Corrosion risk of steel fibre in concrete
저자
Hwang, Jun Pil; Jung, Min Sun; Kim, Moonil; Ann, Ki Yong
DOI
10.1016/j.conbuildmat.2015.10.072
발행일
2015-12
유형
Article
저널명
Construction and Building Materials
권
101
페이지
239 ~ 245