Highly sensitive, fast and wide dynamic range lactate sensor containing solvatochromic sensing membrane by combining the capacitance-to-phase conversion technique

  • Khan, Md. Rajibur Rahaman; 
  • Oh, Seungtaek; 
  • Choi, Giheon; 
  • Lee, Hwa Sung
Citations

WEB OF SCIENCE

17
Citations

SCOPUS

18

초록

We design and develop a low-cost, highly-sensitive, wide dynamic range interdigitated capacitor (IDC) lactate sensor based on the capacitance variation principle. We use Nile red, which has solvatochromic properties and this dye containing sensing membrane deposit into the interdigitated electrode (IDE) to prepare an IDC lactate sensing element. We apply the capacitance-to-phase conversion technique to detect lactate concentrations between 100 nM and 1M by altering the dielectric constant of the membrane. As a result, the capacitance of the IDC sensing element change, introducing a phase shift and producing an output voltage. The sensitivity of the IDC sensing element is 11.28 ns/decade and offer a linear sensing response over a wide dynamic range with a correlation coefficient of R-2 approximate to 0.998. The IDC sensing element also offers an extremely stable response with a fast response time of 1.02 s and fast recovery time of 1.3 s. The relative standard deviation of the stability is 0.024. The proposed IDC lactate sensing element show/exhibit an excellent sensing performance compare to the other lactate-sensors.

키워드

Interdigitated capacitor; Nile red; Sensing membrane; Dielectric constant; Sensitivity; Response time; AMPEROMETRIC BIOSENSOR; BLOOD LACTATE; DEHYDROGENASE; SIGNAL
제목
Highly sensitive, fast and wide dynamic range lactate sensor containing solvatochromic sensing membrane by combining the capacitance-to-phase conversion technique
저자
Khan, Md. Rajibur Rahaman; Oh, Seungtaek; Choi, Giheon; Lee, Hwa Sung
DOI
10.1016/j.snb.2020.127783
발행일
2020-04
유형
Article
저널명
Sensors and Actuators, B: Chemical
권
309