Electrical resistance-based monitoring of CFRP thickness during vacuum assisted resin infusion

Citations

WEB OF SCIENCE

13
Citations

SCOPUS

13

초록

During vacuum-assisted resin infusion (VARI), the thickness of the fabric manufactured into carbon fiber (CF)-reinforced plastic was monitored using electrical resistance, which was correlated with the mechanical and electrical status of the CF with respect to resin infiltration. Furthermore, the electrical network within CF varied in terms of its volume and number of electrical contacts. These phenomena were monitored by installing a Cu tape on the mold. Thus, an in-situ qualitative monitoring system for composite manufacturing was developed utilizing the electrical resistance variations in the fabric. The proposed thickness-monitoring system for VARI can potentially minimize the cost, time, and labor in composite industries.

키워드

manufacturing monitoring; resin infusion; vacuum infusion; COMPOSITES; CARBON
제목
Electrical resistance-based monitoring of CFRP thickness during vacuum assisted resin infusion
저자
Jeong, Woo Nam; Um, Moon-Kwang; Kim, Wie-Dae; Roh, Hyung Doh
DOI
10.1088/2631-6331/acf753
발행일
2023-09
유형
Article
저널명
FUNCTIONAL COMPOSITES AND STRUCTURES
권
5
호
3
페이지
1 ~ 9