Narrow-bore high performance liquid chromatographic method for the determination of cetirizine in human plasma using column switching

  • Kim, Chong-Kook; 
  • Yeon, Kyu Jeong; 
  • Ban, Eunmi; 
  • Hyun, Myung-Ja; 
  • Kim, Jin-Ki; 
  • 외 3명
Citations

WEB OF SCIENCE

18
Citations

SCOPUS

27

초록

An improved column switching high performance liquid chromatographic (HPLC) method was developed for determination of cetirizine in human plasma. Plasma samples were prepared by liquid-liquid extraction using methylene chloride. The samples extracted were initially injected into a clean-up Capcell Pak MF C-8 column and the peaks of cetirizine and internal standard were separated to an analytical C-8 micro-column via column switching device. This analysis showed highly sensitive and selective results. Also, it was successfully applied to evaluate the pharmacokinetics of cetirizine in human volunteers after single oral administration. (c) 2004 Elsevier B.V. All rights reserved.

키워드

cetirizine; column switching; high performance liquid chromatography (HPLC); pharmacokinetics; PHARMACOKINETICS; SERUM
제목
Narrow-bore high performance liquid chromatographic method for the determination of cetirizine in human plasma using column switching
저자
Kim, Chong-Kook; Yeon, Kyu Jeong; Ban, Eunmi; Hyun, Myung-Ja; Kim, Jin-Ki; Kim, Mee-Kyung; Jin, Su-Eon; Park, Jeong-Sook
DOI
10.1016/j.jpba.2004.11.022
발행일
2005-03
유형
Article
저널명
Journal of Pharmaceutical and Biomedical Analysis
권
37
호
3
페이지
603 ~ 609