상세 보기
실내시험을 통한 이중보온관 되메움 대체재료에 관한 연구
- 최봉혁;
- 김진만;
- 유한규
초록
This paper recommends the alternative back-fill material for the pre-insulated pipe based on the results of tests performed using different kinds of backfill material. In this study, laboratory tests were preformed to determine the behavior of the pre-insulated pipe caused by variation on grain size distribution, friction characteristics and earth pressure characteristics of different types of backfill material. Two types of natural sand (fine-grained and coarse-grained sand) and crushed sand, and two types of gravel (10mm, 20mm) were used as backfill material in the laboratory tests. The laboratory test results were analyzed and compared with the pre-insulated pipe backfilled with the standard medium-grained sand. Based on the evaluation and comparison of laboratory test results, it was determined that crushed sand is the most suitable back-fill material that can be used as an alternative for medium grained sand for pre-insulated pipes.
키워드
- 제목
- 실내시험을 통한 이중보온관 되메움 대체재료에 관한 연구
- 제목 (타언어)
- A Study on Alternative Backfill Material for Pre-insulated Pipe through the Laboratory Tests
- 저자
- 최봉혁; 김진만; 유한규
- 발행일
- 2011-09
- 저널명
- 한국지반공학회논문집
- 권
- 27
- 호
- 9
- 페이지
- 5 ~ 11
- 언어
- KOR
- 출판사
- 한국지반공학회
- 발행국가
- 대한민국
- 분량
- 7 페이지
- ISSN
- E 2288-646X
P 1229-2427