건물 외벽의 열관류율 현장 평가 시 환경 변수의 영향 분석

초록

This study proposes a correction regression model to improve the accuracy of in-situ U-value measurements by quantitatively analyzing key environmental factor that affect the thermal transmittance of building exterior walls under various outdoor conditions. Field measurements were conducted on a deteriorated educational building constructed in the 1980s, located in Ansan, Korea, under four conditions: summer/winter and south-/north-facing walls. Data on indoor and outdoor air temperatures, wall surface temperatures, and solar radiation were collected. Hierarchical regression analysis using SPSS revealed high explanatory power (R² ˃ 0.93) and low error rates (8–9%) under winter conditions, whereas the summer south-facing case showed relatively low explanatory power and significantly higher error rates. This suggests that multiple environmental factors interact in south-facing conditions, making it difficult to fully explain U-value variations with the current variables alone. The proposed method provides a methodological basis for enhancing the field applicability of infrared thermography-based U-value evaluations, and further research is needed to incorporate additional variables and refine the model, particularly for summer and south-facing scenarios. Key words

키워드

U-value; Thermal transmittance(열관류율); Thermal performance(단열성능); Building envelope(건물외피); In-situ measurement(현장측정)
제목
건물 외벽의 열관류율 현장 평가 시 환경 변수의 영향 분석
저자
신민재; 송아현; 김예은
발행일
2025-06
유형
Proceeding
저널명
대한설비공학회 학술발표대회 논문집
페이지
469 ~ 472