2행 1열 오스테나이트계 스테인리스강(STS304) 볼트접합부의 종전단 및 블록전단 파단내력에 관한 조사
- 조영준;
- 김태수
SCOPUS
0초록
This study investigates the fracture patterns and ultimate strengths of the double shear two-bolted connections made of austenitic stainless steelSTS304, which is widely used in building structures. The main variables include the plate thickness and end distance in the loading direction. A total of 10 test specimens were planned and fabricated. For specimens with relatively short end distance of less than 24mm, shear-outfractures occurred, while, specimens with end distances of 36mm or more showed typical block shear fracture mode. The strengths of bothdomestic and international design codes (KDS, AISC, AISI, ASCE, AIJ and EC3) and the equations of shear-out and block shear fracturesproposed by the previous researcher were compared with test results. The current standards underestimated the test strengths of double sheartwo-bolted connections of austenitic stainless steel, and shear-out fracture and block shear fracture equations suggested by other researchersbased on carbon steel or duplex stainless steel bolted connections were found to provide good predictions.
키워드
- 제목
- 2행 1열 오스테나이트계 스테인리스강(STS304) 볼트접합부의 종전단 및 블록전단 파단내력에 관한 조사
- 제목 (타언어)
- Investigation on the Shear-out and Block Shear Strength of Austenitic Stainless Steel (STS304) Double Shear Two-Bolted Connections
- 저자
- 조영준; 김태수
- 발행일
- 2023-12
- 유형
- 정기학술지(Article(Perspective Article포함))
- 저널명
- 대한건축학회논문집
- 권
- 39
- 호
- 12
- 페이지
- 245 ~ 252
- 언어
- KOR
- 출판사
- 대한건축학회
- 발행국가
- 대한민국
- 분량
- 8 페이지
- ISSN
- E 2733-6247