상세 보기
페라이트계 스테인리스강(STS430) 이면전단볼트접합부의 구조거동에 관한 실험적 연구
- 김태수;
- 김민성
초록
Many experimental and numerical researches for thin-walled carbon steel and austenitic stainless steel singleshear bolted connections have been conducted and the modified design equations of ultimate strength were proposed. In thisstudy, the tests of double shear bolted connections with bolt arrangements (2×1, 2×2) and end distance parallel to the loadingdirection as main variables were performed. Specimens were planed with a constant dimension of edge distance perpendicularto the loading direction, bolt diameter, pitch and gauge like single shear bolted connections. The test results such as ultimatestrength and fracture mode were compared with those of current design standards. Furthermore, modified block shearequations for double shear bolted connections were suggested.
키워드
- 제목
- 페라이트계 스테인리스강(STS430) 이면전단볼트접합부의 구조거동에 관한 실험적 연구
- 제목 (타언어)
- An Experimental Study on Structural Behaviors of Double Shear Bolted Connections Fabricated with Ferritic Stainless Steel (STS430)
- 저자
- 김태수; 김민성
- 발행일
- 2013-10
- 저널명
- 한국강구조학회 논문집
- 권
- 25
- 호
- 5
- 페이지
- 463 ~ 474
- 언어
- KOR
- 출판사
- 한국강구조학회
- 발행국가
- 대한민국
- 분량
- 12 페이지
- ISSN
- E 2287-4054
P 1226-363X