광양지역 고강도 강관 항타말뚝의 설계효율 향상 방안 연구

Design Efficiency Improvement Method Research for High Strength Steel Pipe Pile at Gwangyang Area

초록

Various pile load tests were carried out at Gwangyang district for 10 different piles in order to analyze the characteristcs of steel pile using high strength steel and high driving energy. Pile drivability results showed that PHC piles needed highest total blow count even with the shortest pile length and high strength steel pipe piles showed smallest total blow count eventhough driven to a more hard ground condition with longer pile length. Pile dynamic analysis results showed that for PHC pile and general steel pipe pile the allowable pile design load was decided by the allowable material strength but for high strength steel pipe pile the design load can be decided according to the ground bearing capacity. Static load test and load transfer test results showed that the pile design efficiency could be improved over 80% allowing lesser number of piles necessary for a more economical solution. Set-up effects was analyzed and regression equation for the site ground condition was derived. Bearing capacity was checked with widely used design equation and the limitation of current design method and future technology development on this subject is dicussed in this paper.

키워드

고강도 강관말뚝; 항타관입성; 현장재하시험; 하중전이시험; high strength steel pipe pile; pile driveability; pile load test; load transfer test
제목
광양지역 고강도 강관 항타말뚝의 설계효율 향상 방안 연구
제목 (타언어)
Design Efficiency Improvement Method Research for High Strength Steel Pipe Pile at Gwangyang Area
저자
나승민; 유한규
DOI
10.12652/Ksce.2011.31.6C.231
발행일
2011-11
저널명
대한토목학회논문집(국문)
권
31
호
6C
페이지
231 ~ 240